Chemi-Coat Standard

$210.55
SKU:
B11105129
Selected Color is
Black
Dark Gray
Navy Gray
Silver Gray
Tile Red
Safety Yellow
Mid Blue
Mid Green
Adding to cart… The item has been added
Chemi-Coat® Standard is a one coat high build epoxy resin coating which offers excellent durability and chemical resistance to aggressive chemicals. It provides a glossy, hygienic and easily cleaned surface. A single coat is usually sufficient. Very …

Product Detail

Chemi-Coat® Standard is a one coat high build epoxy resin coating which offers excellent durability and chemical resistance to aggressive chemicals. It provides a glossy, hygienic and easily cleaned surface. A single coat is usually sufficient. Very porous surfaces should be treated first with 4-Hour Epoxy Primer.

  • Excellent resistance to many chemicals
  • Suitable for a variety of floor and wall surfaces
  • Low solvent content
  • One coat usually sufficient
  • Approved for use on sand and cement screed or concrete with underfloor heating systems (up to 85°F surface temperature)

Discoloration may occur with some chemicals. This is not necessarily an indication of degradation of the coating. For added chemical resistance, particularly to stronger acids, please refer to Watco Chemi-Coat Acid Strength. Please consult our technical department for advice on chemicals not listed.

Chemi-Coat is also available in a Rapid cure version for projects that need less down time, in Cold Cure for applications in colder environments, and Anti-Slip for areas prone to spills and slip hazards.

Warning: Cancer and Reproductive harm image

Specifications

Usage Interior/Exterior: Interior
Finish: Glossy, smooth
Suitable for: Concrete, well-bonded paint, some metals
Recommended Number of Coats: 1
Primer Required: Yes, on very porous surfaces. Use 4 Hour Epoxy Primer.
Curing Time (Hours): 16 Hours in 70°F

How to Apply

Surface Preparation: Concrete and Brick
Concrete to be treated must be dry, at least four weeks old and free of any soft surface laitance, contaminants, and not subject to rising damp. All loose material should be removed. Very smooth bare concrete or concrete with soft surface laitance should be etched with Watco Cemtetch and the area thoroughly hosed off and allowed to dry. Grease or oil should be removed with Watco Bio-D (or a similar degreaser) and the area thoroughly hosed off and allowed to dry. Very smooth previously painted surfaces should preferably be abraded to improve adhesion.

Surface Preparation: Steel
Remove loose or flaking material, rust and any previous coatings by wire brushing or disc grinding to achieve a bright surface. Oil or grease should be removed with Watco Bio-D and the metal then washed with Water and allowed to dry. The coating should be carried out immediately providing flash rusting has not occurred. 

Mixing
Each Chemi-Coat pack consists of a container of curing agent and a container of resin. The curing agent and resin must be thoroughly mixed together with a paint mixer attached to an electric drill until an even color is obtained. 
Important: Once the contents of the pack have been mixed a chemical reaction takes place which causes a rise in temperature and speeds up the curing of the product.

Application
If appearance is critical we recommend the application of a small trial area first. 

Best results are obtained in warm conditions. On horizontal surfaces apply with a medium, pile type roller (not foam) in one coat. On vertical surfaces, two thin coats are recommended. The second coat should be applied within 24 hours.

Data Sheet

Chemi-Coat® Standard is a one coat high build epoxy resin coating which offers excellent durability and chemical resistance to aggressive chemicals. It provides a glossy, hygienic and easily cleaned surface. A single coat is usually sufficient. Very porous surfaces should be treated first with 4-Hour Epoxy Primer.

  • Excellent resistance to many chemicals
  • Suitable for a variety of floor and wall surfaces
  • Low solvent content
  • One coat usually sufficient
  • Approved for use on sand and cement screed or concrete with underfloor heating systems (up to 85°F surface temperature)

Discoloration may occur with some chemicals. This is not necessarily an indication of degradation of the coating. For added chemical resistance, particularly to stronger acids, please refer to Watco Chemi-Coat Acid Strength. Please consult our technical department for advice on chemicals not listed.

Chemi-Coat is also available in a Rapid cure version for projects that need less down time, in Cold Cure for applications in colder environments, and Anti-Slip for areas prone to spills and slip hazards.

Warning: Cancer and Reproductive harm image

Usage Interior/Exterior: Interior
Finish: Glossy, smooth
Suitable for: Concrete, well-bonded paint, some metals
Recommended Number of Coats: 1
Primer Required: Yes, on very porous surfaces. Use 4 Hour Epoxy Primer.
Curing Time (Hours): 16 Hours in 70°F

Surface Preparation: Concrete and Brick
Concrete to be treated must be dry, at least four weeks old and free of any soft surface laitance, contaminants, and not subject to rising damp. All loose material should be removed. Very smooth bare concrete or concrete with soft surface laitance should be etched with Watco Cemtetch and the area thoroughly hosed off and allowed to dry. Grease or oil should be removed with Watco Bio-D (or a similar degreaser) and the area thoroughly hosed off and allowed to dry. Very smooth previously painted surfaces should preferably be abraded to improve adhesion.

Surface Preparation: Steel
Remove loose or flaking material, rust and any previous coatings by wire brushing or disc grinding to achieve a bright surface. Oil or grease should be removed with Watco Bio-D and the metal then washed with Water and allowed to dry. The coating should be carried out immediately providing flash rusting has not occurred. 

Mixing
Each Chemi-Coat pack consists of a container of curing agent and a container of resin. The curing agent and resin must be thoroughly mixed together with a paint mixer attached to an electric drill until an even color is obtained. 
Important: Once the contents of the pack have been mixed a chemical reaction takes place which causes a rise in temperature and speeds up the curing of the product.

Application
If appearance is critical we recommend the application of a small trial area first. 

Best results are obtained in warm conditions. On horizontal surfaces apply with a medium, pile type roller (not foam) in one coat. On vertical surfaces, two thin coats are recommended. The second coat should be applied within 24 hours.

Videos Hide Videos Show Videos